Artikel
This dry block calibrator vs temperature bath analysis helps you pick the option best for your application. See the comparison in 5 areas of consideration.
Artikel
You can bet there is a lot of test and measurement equipment onboard Curiosity. As a test and measurement professional, I’d like to tell you about some of the things I find especially interesting.
Artikel
Get 7 free measurement uncertainty training materials including videos, webinars, & articles. Fluke also offers a paid, online course for deeper knowledge.
Artikel
In metrology, what do you do when your curve-fitting software program doesn’t work because you’re dealing with a non-linear equation? Learn here.
Artikel
Read this short blog post to learn how Fluke Calibration technical support works and get some tips on how to prepare for your tech support call.
Artikel
Fluke experts show you how to calibrate a pressure rotameter including a step-by-step rotameter calibration procedure, calibration curve, and tips.
Artikel
It is becoming my opinion that ISO 17025 needs to be revised. This is the first of a series of blog posts that I will be making to demonstrate why the revision needs to be made.
Artikel
Fluke Calibration recently hosted a webinar (now available in its entirety as free and on-demand) in which a panel of Fluke associates talked about lessons learned and best practices for working, when some employees can work remotely and others must go to the calibration laboratory
Artikel
In this article, electrical calibration expert Marty Kidd explains why someone needs this type of product. He also explains why owners of an old Fluke 5790A should consider moving up to a new 5790B.
Artikel
Lunar reconnaissance is not possible without the precise testing and measurement activity that calibration professionals know so well. Read more here.
Artikel
Another NCSLI conference is in the books. This year, the metrology faithful (and budget funded!) once again gathered to gain knowledge through tutorials and technical presentations, contribute to the industry through attendance of committee meetings, talk to vendors at the exhibition, network with some of the world’s experts in metrology and spend time with old friends. There were so many great things happening that I didn’t even have time to compose a single tweet!
Artikel
Thermoelemente haben in Industrie und Wissenschaft eine große Verbreitung gefunden. Aber es ist unter Umständen nicht ohne Weiteres klar, wie sie funktionieren und wie man sie kalibrieren muss.
Artikel
The Fluke Calibration 1586A and Fluke 2638A are two new data acquisition systems that offer great value and performance. This selection guide will help you understand the differences between the two, the strengths of each, and which one will best meet your current and future needs.
Artikel
Follow the steps as we demonstrate how to link a documenting process calibrator to a drywell to calibrate a 4-20 mA transmitter and probe in a system.
Artikel
Nach der Einstellung des 6003A ist der Leistungs- und Netzqualitätskalibrator 6130B der geeignetste Nachfolger. Wally Miller, Produktexperte von Fluke Calibration, vergleicht die beiden Instrumente und erklärt, warum der 6130B Ihnen ein noch besseres Preis-Leistungs-Verhältnis bietet.
Artikel
Explore analysis of high-frequency error sources in oscilloscope calibration. Gather insights into the causes, impacts, and methods to mitigate these errors to enhance your accuracy.
Artikel
See an example using the Fluke 2271A Industrial Pressure Calibrator to automate testing & calibration of pressure transmitters from 10 in of water to 3000 psi.
Artikel
Discover Fluke resources on how & why to prevent contamination in pressure calibration including videos, webinars, and blog posts. Learn more here.
Artikel
What happens when an electrical standards laboratory’s environmental control system gets old, cranky and hard to maintain? When the lab in question is the Fluke Everett Primary Electrical Laboratory (EPEL), the answer was to replace the air conditioning system, as part of a bigger endeavor to renovate the lab.
Artikel
Should you bring humidity measurement and calibration in house? Learn to answer this question from the perspective of ROI, requirements, and workload.
Artikel
In diesem Blogbeitrag von Fluke Calibration finden Sie 5 bewährte Verfahren zur Kalibrierung von Durchflussmessgeräten, um optimale Betriebseigenschaften Ihrer Durchflussmessgeräte zu gewährleisten. Hier lesen.
Artikel
Every year on May 20, World Metrology Day calls attention to the critical importance of uniform, accurate, traceable measurements in all aspects of the global experience. This year’s theme focuses on “Measurements supporting the global food system” which is in direct response to the challenges we face trying to produce enough safe food to reach a global population of 8 billion people.
Artikel
Elevate lab precision: Combine 5560A Calibrator, Reference Multimeter, Transconductance Amp, MET/CAL & Fluke Premium Care for top-tier accuracy, automation & reliability. Consult our specialists today.
Artikel
Welche Anwendungen lassen sich mit einem Fluke Transkonduktanzverstärker zusätzlich zur Kalibrierung durchführen? Bereitstellung von Gleich- und Wechselstrom mit geringer Unsicherheit, Erkennung von Überspannung und mehr.
Artikel
This video includes reminiscences from Fluke and Fluke Calibration associates who remember what it was like to work at Fluke ”back in the day.”
Artikel
The triple point of argon (83.8058 K ) is one of the most commonly used fixed points for the calibration of standard platinum resistance thermometers (SPRTs) at temperatures below 273.16 K. It’s a defining fixed point of the International Temperature Scale of 1990 (ITS-90). Fluke Calibration recently designed a new Triple Point of argon system with the goal in mind of achieving both efficiency and accuracy in calibrating SPRTs.
Artikel
Kalibrierung verbessert die Sicherheit. Erfahren Sie, wie internationale Sicherheitsnormen und Sicherheitsfunktionen in Fluke Kalibriergeräten die Sicherheit von Laborumgebungen und Mitarbeitern gewährleisten.
Artikel
Read more about why you a pressure controller/calibrator fits the needs of your pressure calibration calibrator and watch our vide about the 6270A Pressure Controller/Calibrator.
Artikel
Lernen Sie die vier verschiedenen Anschlussmethoden und die Einstellungen zum Messen des Widerstands an einem digitalen Handmultimeter, Tischmultimeter und Systemmultimeter kennen.
Artikel
Knowledge of size of source is important for your infrared thermometer calibration. You should use this knowledge in determining a proper size for the thermal radiation source used for the calibration. The three methods to study the amount of source are listed below. Field-of-view Test Field-of-view Specification Sweep
Artikel
Learn about intermediate checks per ISO 17025 (AKA “verification”) vs calibration. Plus, tips for incorporating them to prevent costly manufacturing recalls.
Artikel
What is the difference between the radiometric calibration they speak of and the radiometric calibration I speak of when referring to radiation thermometry? In some aspects, I can answer this by saying “Nothing.” However, I could also answer this by saying “Everything.”
Artikel
Learn how thermocouples work & how to choose calibration equipment, calculate uncertainties, and calibrate thermocouples. Read here and watch the video.
Artikel
Get the quickest answers and fixes when calibration software errors pop up.
Artikel
Consider if your company would be best served by specifying traceability to the SI instead of to your local NMI.
Artikel
Whether you’re speaking to a small group of colleagues at your company or a group of professionals at MSC or NCSLI, here are some tips to help you succeed – and perhaps even enjoy your experience as a public speaker.
Artikel
Writer’s block isn’t limited to metrologists, of course – it’s a universal problem that people in many professions face (even writers). Here are a few simple tips that can help you on your way to greater visibility and respect in your career.
Artikel
Read this short blog post to see how Fluke Calibration contributes in this year's World Metrology Day theme, “Measurements and Light”.
Artikel
A clamp meter typically requires an annual calibration to ensure that it continues to make measurements within the manufacturer’s specifications..
Artikel
In 2012, the Association of German Engineers developed VDI/VDE-2623, which defines and establishes a Calibration Data Exchange Format. VDI/VDE-2623 establishes a rigid Extensible Markup Language (XML) data structure with both required and optional fields
Artikel
Einige können mit Software automatisiert werden, um den Durchsatz bei der Kalibrierung zu erhöhen und Fehler zu verringern
Artikel
Looking to purchase a calibrator from a calibration equipment manufacturer? Grade them with these 10 criteria to make sure you get the best return on investment.
Artikel
If you are currently outsourcing or turning away pressure calibration business, you may be doing so unnecessarily. The barriers to enter the pressure calibration business can be overcome fairly easily.
Artikel
In this Fluke app note, discover the considerations of high-pressure calibration & characterization when manufacturing pressure measurement devices.
Artikel
While there’s no “one size fits all” answer, see this post for helpful guidelines on how often you should calibrate thermometers, test equipment, multimeters, etc.
Artikel
When calibrating a dial gauge, it can be challenging to interpret readings when the pointer is between marks. Learn how to overcome the challenge here.
Artikel
Complete maintenance of a HART transmitter involves three distinct operations: configuration, calibration, and adjustment. Learn more here.
Artikel
In manually testing a pressure switch, calibrators can save you time by reducing steps, automating, & reducing the amount of equipment you need. Learn more.
Artikel
It is a well-established practice in calibration laboratories to use current coils for clamp meter calibrations. Many laboratories either build their own coil, or simply make several loops of a test lead for the purpose of increasing the current value sensed by the clamp meter
Artikel
calibration education, metrology education, web seminars, software user groups, application notes, learn about calibration, learn about metrology
Artikel
Ressourcencenter enthalten Informationsmaterial (Videos, Anwendungsberichte, White Papers und anderes) zu einem bestimmten Thema.
Artikel
Mit einem Mikrobad 7103 benötigen Sie für eine typische Dreipunktkalibrierung von vier hygiene- und lebensmitteltauglichen Tri-Clamp-Sensoren über vier Stunden (ca. 260 Minuten). Dieselbe Kalibrierung mit einem transportablen Kalibrierbad 7109A dauert lediglich ca
Artikel
What is a thermocouple? How does a thermocouple work? Why do thermocouples need to be calibrated?
Artikel
What knocks a digital instrument out of calibration? Learn about the 3 main causes of calibration problems: component shift, drops & overloads.
Artikel
See how Fluke’s long-scale DMMs enable digitizing with emulation, characterization of non-repetitive waveforms & lighted connection terminals. Learn more.
Artikel
Both analog & digital process gauges need to be regularly verified. See the options for verifying in the field or at the bench & the steps to follow.
Artikel
See the steps for how to calibrate a digital multimeter, plus links to 5 free related learning resources including videos, webinars, and articles.
Artikel
See 5 ways to ensure precise measurements in oil & gas custody transfer & see how one calibrator can calibrate the involved pressure & temperature transmitters.
Artikel
The purpose of this paper is to truthfully answer various questions one might have with regard to resistance bridges and readouts after reading some of the sales hype arguing that AC is better than DC or vice versa
Artikel
Der Unternehmensbereich Hart Scientific von Fluke fertigt Platinwiderstandsthermometer, Thermoelemente, Thermistor-Temperatursensoren für die Präzisionstemperaturmessung und -kalibrierung.
Artikel
Eine Präzisionsdigitalthermometeranzeige von Fluke Kalibrierung ist speziell auf die Messung von Temperatursensoren für die Kalibrierung ausgelegt.
Artikel
Die definierenden Messgeräte von ITS-90 (Internationale Temperaturskala von 1990) sind Normal-Platinwiderstandsthermometer (SPRT) und ITS-90 Fixpunktzellen
Artikel
A platinum resistance thermometer (PRT) is a thermometer constructed from a high purity platinum element (wire-wound coil or thin film) placed in a tube of metal or glass and sealed with an inert atmosphere and/or mineral insulator.
Artikel
Automation of the pressure calibration process has many potential benefits, including increasing productivity, ensuring better pressure measurements
Artikel
The first step to selecting the right pressure calibration product is to understand the specifications of the device under test (DUT).
Artikel
Why calibrate test equipment? What makes it go out of cal? What happens when you send equipment for calibration? When should you calibrate? Learn here.
Artikel
Organizational goals are translated into manufacturing/ process requirements. Increasingly individuals and organizations depend on others to meet those requirements, and the tools they use may not all be compatible
Artikel
See a full list of Metal Freeze-Point Cells produced by Fluke and learn more about them here.
Artikel
If you are purchasing a calibrator to calibrate pressure measurement devices, follow these 2 simple steps to ensure you get what you need.
Artikel
To minimize plant downtime and keep operations up and running, follow this guidance to ensure smooth instrumentation calibration.
Artikel
See why Roger Pineche, Director of Engineering at Fluke, says the new 8588A and 8558A are the best benchtop multimeters in terms of stability & accuracy.
Artikel
Get step-by-step instructions on how to accurately calibrate a hygrometer or other humidity sensor including why it’s important, techniques, and tips.
Artikel
Here are some of the most important reasons for you to consider a purchase from Fluke Calibration.
Artikel
Jeff Gust, Chief Corporate Metrologe von Fluke, erklärt, welche Rolle genaue Messungen im Kampf gegen COVID-19 spielen. Sehen Sie sich das kurze Video hier an.
Artikel
Erfahren Sie, welche Kalibriergeräte am besten für Optimierung und Qualitätsmanagement in Fertigungsprozessen der chemischen Industrie, in Kernkraftwerken, der Arzneimittelherstellung sowie der Zellstoff- und Papierindustrie geeignet sind.
Artikel
Erfahren Sie, wie Sie im Rahmen Ihres vorbeugenden Instandhaltungsprogramms Drift während der Kalibrierung an den Stellgliedern für Regelventile vermeiden können.
Artikel
See the advantages of automating temperature calibration, different ways to achieve automation, and the general steps required. Plus, see related resources.
Artikel
Fluke experts show you how to calibrate a pressure transducer including a step-by-step pressure transducer calibration procedure, certificate, and tips.
Artikel
On-the-spot temperature checks using portable thermometers are frequently performed in the field by technicians in order to ensure product quality.
Artikel
Intelligente Proportionalventile spielen in der Prozessindustrie eine wichtige Rolle. Eine genaue Beurteilung der Betriebseigenschaften eines Ventils kann jedoch eine umständliche Routineaufgabe sein.
Artikel
Pairing a Fluke dry well with a handheld documenting calibrator allows for a complete field temperature sensor calibration solution.
Artikel
How to perform a verification test on analog vs digital pressure gauges. Both analog and digital process gauges need to be verified to detect errors related to drift, environment, electrical supply, addition of components to the output loop, and other process changes
Artikel
It's important to select the proper pump and gauge to match the testing application at hand—a good guideline is the testing device should be 4-10 times more accurate than the device being tested.
Artikel
Gas custody transfer flow computers that calculate flow in pipelines by measuring the differential pressure across a flow restriction, such as an orifice plate or other differential pressure flow device, require special calibration to perform at optimum accuracy.
Artikel
A pressure comparator is a convenient instrument for bench pressure calibration. Bench calibrations are performed to maintain reference conditions and to obtain the lowest possible uncertainties. The bench is also a convenient place to inspect, adjust, and repair the devices under test.
Artikel
A deadweight tester is a proven method of pressure calibration that is usually chosen for bench applications when accuracy and reliability are the top requirements. Calibrations are performed at the bench for convenience and to maintain reference conditions.
Artikel
Verifying and documenting the performance and adjusting a HART smart pressure transmitter can require a bucket full of tools. Performing this task with a HART enabled calibrator like the Fluke 754 simplifies the task and reduces what you need to carry.
Artikel
Eine nukleare Reaktion, die sechs Mal heißer ist als die Sonne ... und ein wachsendes Verständnis von Fusionsreaktionen, die den Planeten eines Tages von der Abhängigkeit von fossilen Kraftstoffen befreien können.
Artikel
Unsere Anlage verwendet viele digitale Drucktransmitter-Zellen (Rosemount), um die Füllstände in verschiedenen Tanks zu messen.
Artikel
In einem Werk, das wichtige Komponenten für Luft- und Raumfahrtunternehmen herstellt, kalibriert ein Techniker das Steuerungssystem zur Sicherstellung exakter Temperaturen in den Öfen, in denen Metallteile während der Wärmebehandlungsprozesse gehärtet werden. In einem Werk, das Produkte der Unterhaltungselektronik herstellt, konfiguriert ein Versuchsingenieur ein Datenerfassungssystem, um während des Entwicklungsprozesses eine Reihe von Tests bei einem Prototypen durchzuführen.
Artikel
Selbst in den günstigsten Umgebungen kann sich die Druckkalibrierung als schwierig erweisen. Besondere Erschwernisse bringt das Arbeiten in explosionsgefährdeten Bereichen mit sich.
Artikel
Zur Beurteilung von Steuerventilen und ihrer Funktionsfähigkeit ist es wichtig, dass Sie die verschiedenen Ventilarten und Überprüfungsmöglichkeiten kennen. Bei Absperrventilen zum Öffnen und Schließen ohne analoge Steuerung sind die Tests recht einfach. Es muss nur überprüft werden, ob die Ventile öffnen und schließen.